3-Phase Coupling/Decoupling Network For EFT/Burst Test

3-Phase Coupling/Decoupling Network For EFT/Burst Test

Other Details

Category:

3-PHASE COUPLING/DECOUPLING NETWORK FOR EFT/BURST TEST (CDN-EFT-30)

IEC and ANSI standards cover burst testing of single and three phase AC and DC power ports. The FP-EFT 32M couples the burst into an EUT while Preventing the impulses from polluting the three phase power supply. The FP-EFT 32M has manual coupling path selection to verify the functionality of each path as recommended in the IEC 61000-4-4 Edition 2: 2004. This can also be used to select different coupling paths according to ANSI standards which require a path by path burst test

Technical specifications

1 Max current 15 Amp
2 Max voltage burst 8KV
3 Channels 2 channels for single phase version (Model: CDN-EFT-1P )
4 channels for three phase version (Model: CDN-EFT -3P )
4 Insulation level 10KV
5 Max AC Voltage 415V (Phase – Neutral)
6 Weight 8Kg (Approx)
7 Dimensions W x D x H